UCM-0822A Dust Protection Examination

Japanese



labo.jpg (65840 bytes)UCM-0822A was carried into the industrial technical research center(Tokyo), and the 1st protection-against-dust examinations were performed on July 17, 2003.
machine.jpg (39767 bytes) ucm0822a.jpg (41351 bytes)It is JIS adjusted in IEC529 and this using the talc powder of the 75 micrometers of the maximum particle diameter which are the test method of IP5X and IP6X this time. I had you carry out by C 0920 and the method specified to 4520.
Since it was a sealing formula, it became the examination by normal pressure.
Protection-against-dust examination equipment DT-5S

UCM-0822A which waits for an examination

Actually sent in powder-like powder with air from the equipment upper part, and it was made to float inside examination equipment (it is the quantity of terrible powder), and tested.

Although there is a peephole with a wiper in equipment, it is full of powder during after an operation, and it is not visible.
The surface was in the terrible state after the 8-hour examination.

UCM-0822A-> after a 8-hour examination

powdered.jpg (37066 bytes)
closed.jpg (44358 bytes)

Selection of materials various so far, and a measure and a trial production have been repeated and designed.
It measured with the formal examination equipment in a public organization this time for the first time.

Then, it is since it brought back to the shrine and equipment operation was checked. IP5X level Protection against dust It checked having cleared" performance.

Although examined by putting IP6X of the best grade rank into a view this time, although permeation in a connector portion was very small quantity, it accepted as a result.
It is ", when a measure level is raised for a while the back, since it actually measured and invasion has also prevented present condition processing mostly. Protection against dust " beyond " Dust-proof It turns out that it is likely to arrange to " (IP6X).

 

Surrounding powder is dropped and it takes out from an examination machine.
opentop.jpg (50068 bytes)
The moment of opening a lid for the first time after an examination


Last Update : 2011/09/09